Category: Compliance

  • NFPA 25 Sprinkler Inspections, Explained Simply

    NFPA 25 is the standard most fire marshals use to judge whether a sprinkler system is being looked after. It is long and technical, but the schedule itself is simple once it is laid out.

    Inspection schedule at a glance

    FrequencyWhat is checkedWho usually does it
    Weekly / monthlyControl valves, gauges, alarm devices visible and in placeBuilding staff
    QuarterlyWater-flow alarms, valve supervisory switches, main drainLicensed contractor
    AnnuallyFull system inspection, sprinkler heads, hangers, fire department connectionLicensed contractor
    Every 5 yearsInternal pipe inspection, gauge replacement or calibrationLicensed contractor

    [rp_callout type=”tip” title=”Keep a binder — or a portal”]Inspectors almost always ask for the last inspection report. Contractors that upload reports online save you hunting for paperwork.[/rp_callout]

    Most common deficiencies

    [rp_bars title=”Share of inspections with this finding” suffix=”%”]Obstructed heads (storage too close)|34, Painted or corroded heads|21, Closed or unsupervised valves|12, Missing spare heads cabinet|17, Failed water-flow alarm|9[/rp_bars]

    Storage stacked within 18 inches of sprinkler heads is the number one finding, and it is free to fix. Walk your space before the inspector does.

    Certified fire protection companies

    [rp_businesses category=”fire-sprinkler-repair” limit=”5″]

    [rp_cta category=”fire-sprinkler-repair”]

  • Elevator Entrapment: A Building Manager’s Step-by-Step Plan

    Entrapments are rarely dangerous, but they are always stressful. A clear plan keeps the passenger calm and gets them out quickly — and protects you from liability.

    The first five minutes

    1. Talk to the passenger through the car phone or door. Reassure them that help is coming.
    2. Ask how many people are inside and whether anyone has a medical condition.
    3. Call your elevator contractor’s 24/7 line and give the building address and car number.
    4. If anyone is unwell, call 911 as well.
    5. Never try to open the doors or move the car yourself.

    After the rescue

    Ask the mechanic for a written explanation of the cause. Recurring door-operator or leveling faults are a sign the equipment needs more than a quick reset.

    [rp_bars title=”Most common entrapment causes” suffix=”%”]Door operator faults|41, Power interruptions|22, Controller faults|18, Leveling problems|11, Misuse / overload|8[/rp_bars]

    [rp_callout type=”note” title=”Average response times”]Contractors listed on Repairior in major cities report average entrapment response times between 25 and 45 minutes.[/rp_callout]

    [rp_businesses category=”elevator-repair” limit=”5″]

  • Automatic Gate Safety: What UL 325 Means for Your Property

    UL 325 is the US safety standard for gate operators. Since 2016, new operators must be monitored for entrapment protection, which means the gate will not run if a safety device is missing or failed.

    What a compliant gate has

    • Photo-eye sensors on both sides of the gate path
    • Contact edges on leading edges where pinch points exist
    • An operator that monitors those devices
    • Warning signs on both sides
    • Pedestrian traffic separated from vehicle gates

    Older gates

    Many HOA and apartment gates installed before 2016 have no monitored safety devices. Upgrading usually costs a few hundred dollars per gate — far less than a single injury claim.

    [rp_bars title=”Gates found missing at least one safety device” suffix=”%”]Pre-2010 installations|67, 2010–2016|44, After 2016|12[/rp_bars]

    [rp_businesses category=”automatic-gate-repair” limit=”5″]

    [rp_cta category=”automatic-gate-repair”]